Memmert AtmoCONTROL FDA Version 2.X.X Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Software Memmert AtmoCONTROL FDA Version 2.X.X. Memmert AtmoCONTROL FDA Version 2.X.X User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 40
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
www.memmert.com
|
www.atmosafe.net
100% ATMOSAFE. MADE IN GERMANY.
AtmoCONTROL
SOFTWARE MANUAL
FDA Edition Validatable in according to 21CFR
Part 11 U. S. Food and Drug Administration
Version 2.X.X
Vista de página 0
1 2 3 4 5 6 ... 39 40

Resumo do Conteúdo

Página 1 - AtmoCONTROL

www.memmert.com | www.atmosafe.net100% ATMOSAFE. MADE IN GERMANY.AtmoCONTROLSOFTWARE MANUALFDA Edition Validatable in according to 21CFR Part 11 U. S.

Página 2 - Manufacturer and

10 D30396 | Date 09/2014AtmoCONTROL FDA Version3. Installation3.1 System requirementsCategory Minimum system requirementsProcessorPentium 1 GHzMain m

Página 3 - About this manual

D30396 | Date 09/2014 11AtmoCONTROL FDA VersionWhen starting AtmoCONTROL FDA, you have to login as AtmoCONTROL user with your user name and password

Página 4 - Contents

12 D30396 | Date 09/2014AtmoCONTROL FDA Version4.2.1 Menu barConnect online via EthernetConnect offline from USB deviceConnect offline from databaseD

Página 5 - D30396

D30396 | Date 09/2014 13AtmoCONTROL FDA Version4.2.3 Status barThe status bar gives an overview of the appliances logged on to AtmoCONTROL. Applianc

Página 6 - End user

14 D30396 | Date 09/2014AtmoCONTROL FDA Version4.3.2 Via Ethernet with AtmoCONTROL1. Click on “Help”“Upload license file to device”.2. In the windo

Página 7 - D30396

D30396 | Date 09/2014 15AtmoCONTROL FDA Version4.4.3 Connecting a device using database fi le1. Click on DeviceConnect offline from data-base.2. A

Página 8 - Introduction

16 D30396 | Date 09/2014AtmoCONTROL FDA Version5. Programme5.1 Editor window5.1.1 OverviewIn the Editor window, programmes can be created: sequences

Página 9 - CFR Part 11

D30396 | Date 09/2014 17AtmoCONTROL FDA VersionTo create a programme, drag the individual parameter icons onto the editor thread one after another i

Página 10 - Working with AtmoCONTROL

18 D30396 | Date 09/2014AtmoCONTROL FDA Version5.1.3 Setting parametersIf a parameter icon is selected (clicked) on an editor thread, it is displayed

Página 11 - Programme interface

D30396 | Date 09/2014 19AtmoCONTROL FDA VersionBroad parameter representationparameter representationDepiction in icon barMean-ingDepiction on edito

Página 12 - 1 2 3 4 5 6

Manufacturer and customer serviceMemmert GmbH + Co. KGWilli-Memmert-Straße 90–96D-91186 BüchenbachDeutschland/GermanyPhone: +49 (0)9122 925-0Fax:

Página 13 - Installing the

20 D30396 | Date 09/2014AtmoCONTROL FDA VersionDepiction in icon barMean-ingDepiction on editor threadFunction and adjustment options?15STAND BY15Cha

Página 14 - D30396

D30396 | Date 09/2014 21AtmoCONTROL FDA VersionNarrow parameter representationparameter representationWith the narrow parameter representation, no t

Página 15 - D30396

22 D30396 | Date 09/2014AtmoCONTROL FDA VersionDepiction in icon barMeaning Depiction on editor threadAdjustment options/comments?15STAND BY15Door op

Página 16 - Programme

D30396 | Date 09/2014 23AtmoCONTROL FDA VersionDepiction in icon barMeaning Depiction on editor threadAdjustment options/comments?15STAND BY15Loop J

Página 17 - 11h:30m

24 D30396 | Date 09/2014AtmoCONTROL FDA Version5.2 Simulating the programme sequence (preview)While creating the programme, you can display the prosp

Página 18 - Available

D30396 | Date 09/2014 25AtmoCONTROL FDA Version5.3.3 Transferring programme via EthernetTo be able to transfer a programme via Ethernet, the applia

Página 19 - Tolerance band

26 D30396 | Date 09/2014AtmoCONTROL FDA Version5.4 Programme examplesFor reasons of space, it is not possible to present programme examples with all

Página 20 - STAND BY

D30396 | Date 09/2014 27AtmoCONTROL FDA Version5.4.2 Programme example with door locking1 2 58 63 4Tolerance band1,7 K/min795 °C20 °C45 °C12:00 h

Página 21 - D30396

28 D30396 | Date 09/2014AtmoCONTROL FDA Version5.4.3 Programme example sterilisation1 2 354Tolerance band6180 °C20 °C3:00 h1236470 % 100 %

Página 22

D30396 | Date 09/2014 29AtmoCONTROL FDA Version5.4.4 Programme example loop27 3 56 8941Unload250 °C20 °C0% 80% 0% 80% 0% 80% 0% 80%

Página 23 - D30396

D30396 | Date 09/2014 3AtmoCONTROL FDA VersionAbout this manualPurpose and target groupThis user manual describes the installation and use of the ME

Página 24 - Loading a saved programme

30 D30396 | Date 09/2014AtmoCONTROL FDA Version6. Protocol6.1 Importing protocol from networkTo be able to import a protocol via network, the applian

Página 25 - D30396

D30396 | Date 09/2014 31AtmoCONTROL FDA Version6.3 Exporting protocolWith Protocolexport, you can export a freely definable protocol logging period

Página 26

32 D30396 | Date 09/2014AtmoCONTROL FDA Version8.2.2 Use1. Insert the USER-ID USB stick with the USER-ID file into the USER-ID USB stick with the USE

Página 27 - 1,7 K/min

D30396 | Date 09/2014 33AtmoCONTROL FDA Version8.4 Backup folderYou can set up a backup folder in which AtmoCONTROL saves backup copies of programme

Página 28 - Programme example

34 D30396 | Date 09/2014AtmoCONTROL FDA VersionHere, you can:►add new users►change existing user passwords►assign and remove user rights►remove users

Página 29

D30396 | Date 09/2014 35AtmoCONTROL FDA Version9.4 Traceability by means of a protected audit trail fi leAll actions performed in AtmoCONTROL FDA ar

Página 30 - Protocol

36 D30396 | Date 09/2014AtmoCONTROL FDA Version10. Event codes of the log fi le Log.txt (see page 15)Error codes for Generaon 2012 appliances

Página 31 - Printing

D30396 | Date 09/2014 37AtmoCONTROL FDA Version 000010 Triac heang 1 power module 3 defecve 000001 Triac heang 2 power module 3 defecve 306: Co

Página 32 - Sending

38 D30396 | Date 09/2014AtmoCONTROL FDA VersionIndex21 CFR Part 11 9AAir flap position 21BBackupverzeichnis 33Benutzer wechseln 12CCalendar 22CF

Página 34 - Signing a document

4 D30396 | Date 09/2014AtmoCONTROL FDA Version1. End user licence agreement 62. Introduction 82.1 Description ...

Página 35 - Locking AtmoCONTROL

Memmert GmbH + Co. KGWilli-Memmert-Straße 90-96 | D-91186 BüchenbachTel. +49 9122 925-0 | Fax +49 9122 14585E-Mail: [email protected]/memm

Página 36

D30396 | Date 09/2014 5AtmoCONTROL FDA Version6. Protocol 306.1 Importing protocol from network ...

Página 37 - D30396

6 D30396 | Date 09/2014AtmoCONTROL FDA Version1. End user licence agreementNOTE - IMPORTANT - PLEASE READ THE FOLLOWING AGREEMENT TEXT CAREFULLYThis

Página 38

D30396 | Date 09/2014 7AtmoCONTROL FDA VersionThe user must employ the SOFTWARE PRODUCT only for his own purpose unless expressly agreed otherwise.T

Página 39

8 D30396 | Date 09/2014AtmoCONTROL FDA Version2) If one or several of the above terms should be or become invalid, this does not affect the effective

Página 40 - D30396

D30396 | Date 09/2014 9AtmoCONTROL FDA Version2.3 Advanced functions of the AtmoCONTROL FDA versionWithin a closed system, this specially developed